What is vapor barrier?

What is vapor barrier?

A vapor barrier (or vapour barrier) is often used to refer to any material, typically a plastic or foil sheet that resists diffusion of moisture through wall, ceiling and floor assemblies of buildings and of packaging. Technically, many of these materials are only vapor retarders as they have varying degrees of permeability.
Materials have a moisture vapor transmission rate that is established by standard test methods. One common set of units is g/m²/day. or g/100in²/day. Permeability can be reported in perms, a measure of the rate of transfer of water vapor through a material (1.0 US perm = 1.0 grain/square-foot·hour·inch of mercury ≈ 57 SI perm = 57 ng/s·m2·Pa). Vapor retarding materials are generally categorized as impermeable (≤1 US perm, or ≤57 SI perm), semi-permeable (1-10 US perm, or 57-570 SI perm), and permeable (>10 US perm, or >570 SI perm).

Materials used as vapor retarders

Aluminum foil, 0.05 US perm (2.9 SI perm). Paper-backed aluminum.
Polyethylene plastic sheet, 4 or 6 thou (0.10 or 0.15 mm), 0.03 US perm (1.7 SI perm). Advanced Polyethylene vapor retarders that pass the ASTM E 1745 standard tests ≤0.3 US perm (17 SI perm). Asphalt-coated kraft paper, often attached to one side of fiberglass batts, 0.40 US perm (22 SI perm). Metallized film Vapor retarder paints (for the air-tight drywall system, for retrofits where finished walls and ceilings will not be replaced, or for dry basements: can break down over time due to being chemically based). Extruded polystyrene or foil-faced foam board insulation. Exterior grade plywood, 0.70 US perm (40 SI perm). Most sheet type monolithic roofing membranes. Glass and metal sheets (such as in doors and windows).

Usage

In modern construction, vapor barriers have become controversial.[1] but their use is legislated within the building code of some countries (such as the U.S., Canada, Ireland, England, Scotland & Wales). Current building science recommendations are to vary the location of the vapor retarder in the thermal envelope (exterior walls and ceiling/roof) depending on the climate zone. Some building codes require an interior vapor retarder in heating-dominated climates or an exterior vapor retarder in cooling-dominated climates. In most climates, however, it is often better to have a vapor-open building assembly, meaning that walls and roofs should be designed to dry:[2] either to the inside, the outside, or both.

Basements

In areas below foundation level (or, subgrade areas), particularly those formed in concrete, vapor retarder placement can be problematic, as moisture infiltration from capillary action can exceed water vapor movement outward through framed and insulated walls.

Under concrete slabs

A slab-on-grade or basement floor should be poured over a cross-laminated polyethylene vapor barrier over 4 inches (10 cm) of granular fill to prevent wicking of moisture from the ground and radon gas incursion.

Steel buildings

Inside a steel building, water vapor will condense whenever it comes into contact with a surface that is below the dew point temperature. Visible condensation on windowpanes and purlins that results in dripping can be somewhat mitigated with ventilation; however insulation is the preferred method of condensation prevention.

Packaging

Main articles: Package testing , Moisture vapor transmission rate, Oxygen transmission rate, and Carbon dioxide transmission rate The ability of a package to control the permeation and penetration of gasses is vital for many types of products. Tests are often conducted on the packaging materials but also on the completed packages, sometimes after being subjected to flexing, handling, vibration, or temperature.